 REDUCE THE RISK

RISK…who can afford to take one?

As per the dictionary; RISK n. “Chance of harm or loss, etc.”   or v. “To put in danger or to take the chance of.”

FACT:  360 people die every day from infection. 

FACT:  Because a sterilizer may be new, does not mean every pack or tray is guaranteed to be sterile.

FACT:  Operator error is the primary cause of sterilizer failure usually caused by overloading the sterilizer.  Operator error in assembling a tray or pack can also cause “cold spots” where the sterilant is ineffective.

 

Biological spore testing will reduce the risk, as it is the only valid proof that your sterilizer is sterilizing.  Chemical indicators only indicate that an item has been exposed to a sterilant (see Sterilization Supplies for a complete explanation of the various types of chemical indicators available).  Spore testing using biological indicators (paper strips inoculated with millions of micro-organisms) are as resistant to a sterilizer as are common viruses; germs; mold and bacteria.  Our spore strips have the dual spores “G. Stearothermophilus and B. Atrophaeus” spores.  The Geobacillus stearothermophilus spores require steam sterilization at 121.1°C to 135°C (250°F to 275°F), Low Temperature Steam w/Formaldehyde and Chemiclave®.  Bacillus atrophaeus spores are for use in Ethylene Oxide (600 mg/L), Dry Heat Sterilization (Dvalue calculated at 160°C) and formaldehyde fumigation.
 
Third party spore testing will give you peace of mind and assurance that your sterilizer and its operator are performing properly and will reduce the risk of passing viral and bacterial infections to your patients and staff.  Accurate sterilization records and documented test reports will provide legal documentation should litigation occur.

The CDC and many other agencies recommend that sterilizers should be monitored WEEKLY using biological indicators.  This is also required by law in some states. Check for your states guidelines under your industry heading in our menu; if your industry is not listed, call us for updated laws or regulations.  

 

DID YOU KNOW?

§       Autoclave Testing Service, Inc. is one of the first companies nationwide to offer a Mail-In sterilizer monitoring service using biological indicators.  Serving the healthcare industry throughout the United States and Canada since 1986, we have thousands of satisfied customers.

§       We have on-line test results allowing you to access your results at your convenience!  Your Sterilizer Test Report (STR) is posted on-line upon completion of culturing, offering minimum turn-around time.

§       We have 24-hour test results for Steam sterilizers!

§       We have a comprehensive Glossary of Terms related to the sterile processing area (scroll below to view the Glossary).  This is invaluable information, assisting you with this important area of your facility.

ATS, Inc. now stocks sterilization pouches, sterilizer cleaners, chemical indicator products, sterilizers (new and used), ultrasonic cleaners, water distillers, and more!  (see Supplies).

GLOSSARY OF TERMS USED: