MAIL IN TESTING

IN OFFICE TESTING

TEST RESULTS

SUPPLIES

FREE TRIAL TEST

CONTACT US

 
SELECT YOUR COUNTRY
     
 
HOME
ABOUT US
FAQ
SALES AND SUPPORT
PRODUCTS
SERVICES
 
PROGRAMS
STANDARD PROGRAMS
ECONOMY PLUS PROGRAM
ECONOMY PROGRAM
IN OFFICE TESTING
STERILIZATION SUPPLIES
FEATURES
 
BECOME COMPLIANT
DENTAL REGULATIONS
MEDICAL REGULATIONS
TATTOO REGULATIONS
THE CDC
REDUCE THE RISK
PROOF OF STERILIZATION
VERIFIED TEST REPORTS
DISPLAY CERTIFICATE
 
AUTOCLAVE REPAIR
AUTOCLAVES NEW & USED
INFECTION CONTROL SUPPLIES
PROMOTIONS
REFERRAL REWARDS
SATISFACTION GUARANTEE
 
 

___________

 

CSA Regulations for daily monitoring with Biological Indicators, Bowie-Dick Tests and Chemical Indicators are now required.

VIEW CANADA REGULATIONS

Test Daily only $1.59 per test!

Contact our Sales Department

877/287/1199

___________

 

 
 
 
 
 
PROOF OF STERILIZATION:

The sterility assurance predicament:  There is no practical way of verifying the sterility of individual objects that have been through a sterilizer. 

Therefore, it is imperative that the three critical steps in testing the efficacy of the sterilizer process is followed which include:  Physical monitoring, the use of external and internal CI (chemical indicators) and the frequent use of BI’s (biological indicators).

Physical Monitoring:  Includes the recording of the sterilizer’s temperature, time and pressure on digital printouts, recorders, displays and/or gauges.  This provides real-time assessment of the sterilization cycle and a permanent record in the form of a chart or printed readout.  Physical monitoring helps to detect malfunctions sooner allowing you to take corrective actions.

Chemical Indicators:  Chemical Indicators are a critical part of an effective quality assurance program and should be used in conjunction with physical monitoring and biological indicator testing.  Best practices recommend that external and internal CI’s should be used for all items being sterilized.  Chemical indicators range from Class 1,2,3,4 and 5 as briefly described below: (See Sterilization Supplies for our full line of chemical indicators).

  •      Class 1 chemical indicator:  A process indicator often referred to as an external indicator.  They distinguish between processed or unprocessed items and indicate that they were exposed the sterilizer.  These are seen as indicators on pouches, sterilizer tapes or labels.

  •      Class 2 chemical indicator:  Is designed for a specific test procedure (e.g. The Bowie-Dick test used to determine if air removal has been adequate in dynamic-air-removal sterilizers)

  •      Class 3 chemical indicator:  Is a single parameter indicator.  It is designed to react to one of the critical parameters of sterilization.

  •      Class 4 chemical indicator:  Is a multi-parameter indicator.  It is designed to react to two or more of the critical parameters of sterilization.

  •      Class 5 chemical indicator:  Is an integrating indicator.  This chemical indicator reacts to all three parameters of sterilization which include proper amount of time, temperature and pressure of the sterilizer.  They have been correlated to the performance of a biological indicator when used according to the manufacturers conditions noted on the label.

Biological Indicators:  (Also known as spore tests or BI’s) are paper filter strips inoculated with millions of spores.  They provide the only way the sterility process can be measured.  Sterilizer manufacturers validate their sterilizers by using biological indicators, and therefore BI’s should be used to check the sterilizer’s effectiveness frequently and on a routine basis. The CDC, The Joint Commission, AAMI and others are now recommending DAILY monitoring of sterilizers using biological indicators (or at least each day the sterilizer is being used). 

It is also recommended that a PCD be used when testing a sterilizer.  A “PCD” is a process challenge device.  This device is to be equal or greater than the most difficult item that is routinely sterilized such as a large pack or tray.  Often the device is assembled ‘in-house’ using towels folded and stacked with a BI (biological indicator) or CI (chemical indicator) in the center of the stacked towels.  A PCD should be representative of a package or tray that routinely is processed through the sterilizer.  PCD’s are also sold commercially (see Sterilization Supplies that are FDA cleared, although there is no universally accepted PCD for table top sterilizers.  PCD’s that are commercially available present a challenge to your sterilizer using a BI or CI in the center of the pack, but it may not represent your own particular tray or pack, which is why we recommend that the user sets up their own PCD “device” as noted above.  For more technical information, contact us at info@autoclavesporetesting.com.

PROOF OF STERILIZATION CONCLUSION:  If your facility is following the guidelines as noted above and as recommended by The CDC, The Joint Commission, and AAMI, and you have documented Third-Party Laboratory results of biological and chemical indicator test results, this will ensure you, your staff and your clients that your sterilizer is functioning correctly and is in fact sterilizing.

 
ONLINE STORE:  (SELECT YOUR COUNTRY)          
  Title Description
Biological Indicators (Spore Testing)

 

In-Office and Mail-To-Lab Testing! Verify the sterilization process of all steam sterilizers which include Statim, Midmark, Tuttnauer, Lisa, Mocom and Pelton & Crane sterilizers.

In-Office Testing as low as $1.59/test!

Mail-To-Lab Testing as low as $2.96/week!

Bowie-Dick Tests

 

Bowie-Dick Test Packs should be used daily to evaluate the performance of air-removal (vacuum) system of dynamic pre-vacuum type sterilizers.   Available as test cards or preassembled test packs.  

As low as $2.98 per test!

Chemical Indicators, Class 5 Integrators

 

Internal CI’s should be used within each pouch or package, tray, or container. Class 5 Integrators should be used in conjunction with physical monitoring and biological indicator testing for verifying the efficacy of a sterilization system. (See AAMI ST79:2006) 

Indicator Tape

 

Indicator tapes provide a seal for sterilization packs and an immediate identification of processed items.  Dispensers available for all sizes.

Recordkeeping

 

Recordkeeping is a must for all sterile processing departments.  This ensures accountability and allows operators to trace errors to their source. Tips on sterilizer maintenance and technical advice are included with each book.

Sterilization Crepe Paper

 

Teal green Crepe Paper is compatible with types of sterilization processes including Steam, EO Gas, and Gamma Radiation. Click here to see all sizes!

Sterilization Pouches/Bags

 

Our easy peel-and-seal pouches work with Steam, Chemical Vapor, and Ethylene Oxide Gas sterilization procedures. Choose from 13 different sizes!

Sterilization Tubing

 

Our high quality sterilizer tubing comes in 3 different sizes. Buy in case quantity and save!

Sterilization Wrap

 

Blue non-woven SMS wrap and teal green crepe paper are compatible for most sterilization processes. Click here for available sizes.

Sterilizer Cleaner

 

Click to view all brands of sterilizer cleaner! We stock Duraclean, Omni-Cleaner, Chamber-Brite.

 

GLOSSARY OF TERMS USED:

 

  Full services provider in the United States and Canada for biological indicators, chemical indicators, spore testing, autoclave testing.

(c)opyright 2010 Autoclave Testing Service Inc Spore Strip Testing, Daily spore testing, Sterility Assurance Programs, Dental, Medical, Tattoo, Clinic, Autoclave Spore Testing, Daily Testing